Chemical Name: Electron Fluoride Solution
CAS No.: 406-78-0
Appearance: Colorless Clear Liquid
Chemical Name: Electron Fluoride Solution
CAS No.: 406-78-0
Appearance: Colorless Clear Liquid
Electron Fluoride Solution Quick Details
Chemical Name: Electron Fluoride Solution
CAS No.: 406-78-0
Appearance: Colorless Clear Liquid
Electron Fluoride Solution Series
1.Fluorocarbon cooling medium
Fluorocarbon cooling medium Description
Fluorocarbon-cooled working fluids are high-permeability, high- permeability perfluorinated liquid compounds with high dielectric constant, ideal chemical inertness, excellent thermal conductivity, and good system matching compatibility. This series of products are widely used in various temperature-controlled heat dissipation systems. This product is widely used in immersed phase liquid cooling of data center servers, and is also widely used in various stages of semiconductor manufacturing to cool and cool (such as wafer manufacturing coolers, dry Etching and tempering upper and lower electrodes for temperature control, wafer pattern preparation, exposure table, and wafer test system.
High and low temperature cooling control, etc.; high-speed train power supply inverter, lithium battery power car cooling temperature control, nuclear power, UHV power grid and military radar system, wind turbine internal heating components cooling system coolingand cooling.
Fluorocarbon cooling medium Features
Ideal chemical inertness, can be widely used in various temperature control heat dissipationoccasions.
Single-phase cooling has a lower gas pressure, which can reduce the sealing requirements of the equipment and the maintenance in the later maintenance, and reduce thecost.
Non-dangerous goods or not explosion, no flashpoint
Electrical insulation is good, with a very high breakdown voltage greater than50KV.
A dielectric constant below 2 does not deplete data in data center applications.
Good fluidity, low viscosity compared to clean water; goodheat dissipation in temperature controlsystems.
Non-toxic, harmless andnon-irritating
Fluorocarbon cooling medium Typical Properties
Dielectric constant | 1.85 |
Breakdown voltage Content measurement) | 48KV |
Surface Tension | 16.7mN/m |
Boiling point | 110~115°C |
Density | 1.812g/ml |
Volume resistivity | 1.4×1014 |
Coefficient of expansion | 0.0015 |
Saturated water content | 23.4ppm |
Critical temperature | —— |
PH value | —— |
Flash point | N/A |
Burning process | N/A |
ODP | 0 |
GWP | Low |
Specific heat (25 ° C) | 1.431J/g°C |
Thermal Conductivity | 0.0831 |
Heat of vaporization | 136J/g°C |
Viscosity | 0.87 mPa.s |
2. HH-705
HH-705 Description
Cooling Medium HH-705 is a highly stable fluoroether liquid with high dielectric strength, ideal chemical inertness, excellent heat transfer properties and good system compatibility. This product is widely used in various temperature control cooling systems, such as heat pipe cooling system (soaking plate, inflation plate and various types of heat pipe radiators), lithium battery power vehicles (motor, battery box, etc.) Cooling and cooling in all aspects of production and manufacturing (such as wafer manufacturing cooler, dry etching upper and lower electrode cooling temperature control, chip pattern preparation exposure machine, chip test system high and low temperature cooling control, chip sorting equipment, etc.), military Cooling and cooling of the heat dissipation system of the internal heating components of the radar system and the wind power generator.
HH-705 Features
It has good chemical inertness, it can be widely used in various temperature controlled heat dissipation applications.
Non-dangerous goods, no explosion, no flash point
Good electrical insulation, with a very high breakdown voltage greater than40KV。
Low viscosity, good heat dissipation in the temperature control system.
Non-toxic, harmless and non-irritating
Environmentally friendly, with 0 ODP values and very low GWP value products
HH-705 Typical Properties
Name | HH-705 | Dielectric constant | 5.82 |
Dielectric strength | >40KV | Surface Tension | 1.154mN/m |
Boiling point | 73°C | density | 1.52g/ml |
Specific heat capacity | 137.5J/g°C | Vaporization heat | 132.7J/g°C |
Saturated water content | 647ppm | Viscosity | 0.61 CPS |
PH | Not applicable | Flash point | N/A |
Combustion process; | N/A | ODP | 0 |
GWP | 33 | Vapor Pressure 20℃ | 13kpa |
3. Fluorocarbonalkanesolvent
Fluorocarbonalkanesolvent Usage
Solvent:anti-fingerprintliquidandlubricantthinner
Cleaning:metaldegreasingcleaning,plasticcleaning,resincleaning,dust
removal
Heatmedium:secondaryrefrigerant,coldload
Usedtoreplace3MTMNovecTM, DupontTMVertrel®solvents
Fluorocarbonalkanesolvent Advantages
Colorless,odorless,notburning
Lowsurfacetension,lowviscosity,lowlatentheatofevaporation
Excellentheatresistance,chemicalresistanceandhydrolysisresistance
TheperformanceisclosesttoCFCsandtheODPvalueiszero
FluorocarbonalkanesolventTypical Properties
Boilingpoint | 90-110℃ |
density | 1.766(g/ml,25℃) |
Viscosity | 0.62(cst) |
VaporPressure | 6(KPa, 25℃) |
Perfluoro-n-heptane | ≈27% |
Perfluoropropylcyclohexylether | ≈6% |
Perfluorobutylcyclopentylether | ≈36% |
Perfluoro-n-octane | ≈23% |
Perfluorocyclodecylether | ≈1.5% |
Moisture | <50ppm |
4. Hexafluoropropylenetrimer
HexafluoropropylenetrimerUsage
Solvent:lubricantdiluent
Cleaning:metaldegreasingcleaning,plasticcleaning,resincleaning,dustremoval
Syntheticsurfactantsandpolymers
Heatmedium:secondaryrefrigerant,carryingcold
Usedtoreplace3MTMNovecTM, DupontTMVertrel®solvents
Hexafluoropropylenetrimer Advantages
Colorless,odorless,notburning
Lowsurfacetension,lowviscosity,lowlatentheatofevaporation
Excellentheatresistance,chemicalresistanceandhydrolysisresistance
TheperformanceisclosesttoCFCsandtheODPvalueiszero
Hexafluoropropylenetrimer Typical Properties
Boilingpoint | 108℃ |
density | 1.75(g/ml,25℃) |
Viscosity | 0.68(cst) |
VaporPressure | 5.5(KPa,25℃) |
SurfaceTension | 13(dyn/cm) |
content | >99% |